5,356 research outputs found

    Reluctance Accelerator Efficiency Optimization via Pulse Shaping

    Get PDF
    Reluctance accelerators are used to apply linear forces to ferromagnetic projectiles via solenoids. Ef ciency increases for a single-stage reluctance accelerator were produced by manipulating the input current pulse supplied by a discharging capacitor. The development of a theoretical model allowed for the calculation of optimized pulse shapes. A digital pulsewidth modulated switching method was used to control the current pulse shape using an Arduino Uno microcontroller, which supplied signals to the gate of a MOSFET transistor that controlled the current to the system solenoid. An ef ciency increase of 5.7% was obtained for a reluctance accelerator with an optimized current pulse shape in comparison to a capacitor discharge with no pulse shapin

    Influence of third-body particles originating from bone void fillers on the wear of ultra-high-molecular-weight polyethylene

    Get PDF
    Calcium sulfate bone void fillers are increasingly being used for dead space management in infected arthroplasty revision surgery. The presence of these materials as loose beads close to the bearing surfaces of joint replacements gives the potential for them to enter the joint becoming trapped between the articulating surfaces; the resulting damage to cobalt chrome counterfaces and the subsequent wear of ultra-high-molecular-weight polyethylene is unknown. In this study, third-body damage to cobalt chrome counterfaces was simulated using particles of the calcium sulfate bone void fillers Stimulan® (Biocomposites Ltd., Keele, UK) and Osteoset® (Wright Medical Technology, TN, USA) using a bespoke rig. Scratches on the cobalt chrome plates were quantified in terms of their density and mean lip height, and the damage caused by the bone void fillers was compared to that caused by particles of SmartSet GMV PMMA bone cement (DePuy Synthes, IN, USA). The surface damage from Stimulan® was below the resolution of the analysis technique used; SmartSet GMV caused 0.19 scratches/mm with a mean lip height of 0.03 µm; Osteoset® led to a significantly higher number (1.62 scratches/mm) of scratches with a higher mean lip height (0.04 µm). Wear tests of ultra-high-molecular-weight polyethylene were carried out in a six-station multi-axial pin on plate reciprocating rig against the damaged plates and compared to negative (highly polished) and positive control plates damaged with a diamond stylus (2 µm lip height). The wear of ultra-high-molecular-weight polyethylene was shown to be similar against the negative control plates and those damaged with third-body particles; there was a significantly higher (p < 0.001) rate of ultra-high-molecular-weight polyethylene wear against the positive control plates. This study showed that bone void fillers of similar composition can cause varying damage to cobalt chrome counterfaces. However, the lip heights of the scratches were not of sufficient magnitude to increase the wear of ultra-high-molecular-weight polyethylene above that of the negative controls

    The effectiveness of education in the recognition and management of deteriorating patients: A systematic review

    Get PDF
    publisher: Elsevier articletitle: The effectiveness of education in the recognition and management of deteriorating patients: A systematic review journaltitle: Nurse Education Today articlelink: http://dx.doi.org/10.1016/j.nedt.2016.06.001 content_type: article copyright: © 2016 Elsevier Ltd. All rights reserved

    A novel mixed-method approach to assess children's sedentary behaviours

    Get PDF
    Purpose: Accurately measuring sedentary behavior (SB) in children is challenging by virtue of its complex nature. While self-report questionnaires are susceptible to recall errors, accelerometer data lacks contextual information. This study aimed to explore the efficacy of using accelerometry combined with the Digitising Children’s Data Collection (DCDC) for Health application (app), to capture SB comprehensively. Methods: 74 children (9–10 years old) wore ActiGraph GT9X accelerometers for 7 days. Each received a SAMSUNG Galaxy Tab4 (SM-T230) tablet, with the DCDC app installed and a specially designed sedentary behavior study downloaded. The app uses four data collection tools: 1) Questionnaire, 2) Take a photograph, 3) Draw a picture, and 4) Record my voice. Children self-reported their SB daily. Accelerometer data were analyzed using R-package GGIR. App data were downloaded and individual participant profiles created. SBs reported were grouped into categories and reported as frequencies. Results: Participants spent, on average, 629 min (i.e., 73% of their waking time) sedentary. App data revealed most of their out-of-school SB consisted of screen time (112 photos, 114 drawings, and screen time mentioned 135 times during voice recordings). Playing with toys, reading, arts and crafts, and homework were also reported across all four data capturing tools on the app. On an individual level, data from the app often explained irregular patterns in physical activity and SB observed in accelerometer data. Conclusion: This mixed methods approach to assessing SB adds context to accelerometer data, providing researchers with information needed for intervention design

    An international comparative study of blood pressure in populations of European vs. African descent

    Get PDF
    Background: The consistent finding of higher prevalence of hypertension in US blacks compared to whites has led to speculation that African-origin populations are particularly susceptible to this condition. Large surveys now provide new information on this issue. Methods: Using a standardized analysis strategy we examined prevalence estimates for 8 white and 3 black populations (N = 85,000 participants). Results: The range in hypertension prevalence was from 27 to 55% for whites and 14 to 44% for blacks. Conclusions: These data demonstrate that not only is there a wide variation in hypertension prevalence among both racial groups, the rates among blacks are not unusually high when viewed internationally. These data suggest that the impact of environmental factors among both populations may have been under-appreciated

    Validating the Sedentary Sphere method in children: does wrist or accelerometer brand matter?

    Get PDF
    This study aimed to validate the Sedentary Sphere posture classification method from wrist-worn accelerometers in children. Twenty-seven 9-10-year-old children wore ActiGraph GT9X (AG) and GENEActiv (GA) accelerometers on both wrists, and activPAL on the thigh while completing prescribed activities: five sedentary activities, standing with phone, walking (criterion for all 7: observation) and ten minutes free-living play (criterion: activPAL). In an independent sample, 21 children wore AG and GA accelerometers on the non-dominant wrist and activPAL for two days of free-living. Percent accuracy, pairwise 95% equivalence tests (±10% equivalence zone) and intra-class correlation coefficients (ICC) analyses were completed. Accuracy was similar, for prescribed activities irrespective of brand (non-dominant wrist: 77%-78%; dominant wrist: 79%). Posture estimates were equivalent between wrists within brand (±6%, ICC>0.81, lower 95% CI>0.75), between brands worn on the same wrist (±5%, ICC>0.84, lower 95% CI>0.80) and between brands worn on opposing wrists (±6%, ICC>0.78, lower 95% CI>0.72). Agreement with activPAL during free-living was 77%, but sedentary time was underestimated by 7% (GA) and 10% (AG). The Sedentary Sphere can be used to classify posture from wrist-worn AG and GA accelerometers for group-level estimates in children, but future work is needed to improve the algorithm for better individual-level results

    The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty

    Get PDF
    Objectives: Bone void fillers are increasingly being used for dead space management in arthroplasty revision surgery. The aim of this study was to investigate the influence of calcium sulphate bone void filler (CS-BVF) on the damage and wear of total knee arthroplasty using experimental wear simulation. Methods: A total of 18 fixed-bearing U2 total knee arthroplasty system implants (United Orthopedic Corp., Hsinchu, Taiwan) were used. Implants challenged with CS-BVF were compared with new implants (negative controls) and those intentionally scratched with a diamond stylus (positive controls) representative of severe surface damage (n = 6 for each experimental group). Three million cycles (MC) of experimental simulation were carried out to simulate a walking gait cycle. Wear of the ultra-high-molecular-weight polyethylene (UHMWPE) tibial inserts was measured gravimetrically, and damage to articulating surfaces was assessed using profilometry. Results: There was no significant difference (p  >  0.05) between the wear rate of implants challenged with CS-BVF (3.3 mm3/MC (95% confidence interval (CI) 1.8 to 4.8)) and the wear rate of those not challenged (2.8 mm3/MC (95% CI 1.3 to 4.3)). However, scratching the cobalt-chrome (CoCr) significantly (p < 0.001) increased the wear rate (20.6 mm3/MC (95% CI 15.5 to 25.7)). The mean surface roughness of implants challenged with CS-BVF was equivalent to negative controls both after damage simulation (p = 0.98) and at the conclusion of the study (p = 0.28). Conclusion: When used close to articulating surfaces, a low-hardness, high-purity CS-BVF had no influence on wear. When trapped between the articulating surfaces of a total knee arthroplasty, CS-BVF did not scratch the surface of CoCr femoral components, nor did it increase the wear of UHMWPE tibial inserts compared with undamaged negative controls

    Molecular Genetics of T Cell Development

    Get PDF
    T cell development is guided by a complex set of transcription factors that act recursively, in different combinations, at each of the developmental choice points from T-lineage specification to peripheral T cell specialization. This review describes the modes of action of the major T-lineage-defining transcription factors and the signal pathways that activate them during intrathymic differentiation from pluripotent precursors. Roles of Notch and its effector RBPSuh (CSL), GATA-3, E2A/HEB and Id proteins, c-Myb, TCF-1, and members of the Runx, Ets, and Ikaros families are critical. Less known transcription factors that are newly recognized as being required for T cell development at particular checkpoints are also described. The transcriptional regulation of T cell development is contrasted with that of B cell development, in terms of their different degrees of overlap with the stem-cell program and the different roles of key transcription factors in gene regulatory networks leading to lineage commitment
    corecore